$$\boxed{A = -\log T = \varepsilon b c} \qquad A_\lambda = b\sum \varepsilon_{i,\lambda} c_i$$
T 10% ↔ A 1; T 1% ↔ A 2. Best precision at A = 0.434 (T = 1/e); work at 0.2–0.8.
Deviations: real (c above about 0.01 M), chemical (dimerisation, dissociation: Cr₂O₇²⁻/HCrO₄⁻), instrumental (polychromatic light, stray light → negative deviation at high A).
Stray light: A’ = −log[(T + s)/(1 + s)]; true 2.00 with 1% stray reads 1.70.
Isosbestic point: only two interconverting absorbers.
LOD = 3s_blank/slope; LOQ = 10s.
Standard addition corrects matrix effects; internal standard corrects fluctuations.
Job’s maximum at x_L = n/(n + 1): 0.5 ML, 0.67 ML₂, 0.75 ML₃.
Photometric titration shapes: titrant absorbs → flat then rise; product absorbs → rise then flat; analyte absorbs → fall then flat; analyte and titrant → V.
AAS: hollow-cathode lamp of the analyte (lines too narrow for a continuum); graphite furnace gives lower LOD; cold vapour for Hg; hydride generation for As, Se, Sb, Bi, Sn.
Dynamic: τ falls with [Q], more quenching on heating. Static: τ unchanged, less quenching on heating. k_q above about 10¹⁰ L mol⁻¹ s⁻¹ → static contribution.
Electroanalytical methods
Reference
vs SHE (25 °C)
SCE (sat. KCl)
+0.241 V
Ag/AgCl (sat. KCl)
+0.197 V
Nernst: E = E° − (0.05916/n) log(a_Red/a_Ox). ISE slope 59.16/z mV per decade.
Pulse methods: lower LOD; DPP gives a peak. ASV: pre-concentrate Pb, Cd, Cu, Zn into Hg, then strip.
CV criterion (reversible, 25 °C)
Value
ΔEp
≈ 59/n mV (2.22RT/nF ≈ 57/n), independent of v
i_pa/i_pc
1
i_p
2.69 × 10⁵ n^(3/2) A D^½ C v^½ (A, cm², cm² s⁻¹, mol cm⁻³, V s⁻¹)
ΔEp grows with v → quasi-reversible. No return peak → irreversible or fast chemical step. Ratio < 1 recovering at fast scans → EC. i_p ∝ v → adsorbed species.
Amperometric titrations: analyte reducible → L; titrant reducible → reversed L; both → V. Karl Fischer: biamperometric (dead-stop).
Thermoanalytical methods
Technique
Measures
Sees melting?
TGA
mass
no
DTG
dm/dT
no
DTA
ΔT (sample − reference)
yes, semi-quantitative
DSC
heat flow
yes, ΔH from area
CaC₂O₄·H₂O (146.11)
Loss (% of original)
Residue
−H₂O
12.3
87.7% CaC₂O₄
−CO
19.2
68.5% CaCO₃
−CO₂
30.1
38.4% CaO
CO step: endothermic in N₂, exothermic in air (CO burns).
CuSO₄·5H₂O: 2 + 2 + 1 H₂O (7.22% each; last one held most firmly); CuSO₄ 63.9%; CuO 31.9%.
Faster heating, bigger sample, product gas in purge → steps at higher T. Buoyancy → apparent mass gain.
Ca/Mg oxalate mixture: mass loss between CaCO₃ + MgO and CaO + MgO plateaus is CO₂ from CaCO₃ alone.