Skip to content

Mass Spectrometry, Electron Spectroscopy and Microscopy

CSIR NET chemistry: ionisation methods, isotope patterns and charge states in MS; XPS, UPS and Auger; SEM, TEM, STM and AFM for inorganic materials.

  • 17 min read
  • Updated
On this page · 12 sections
  1. Prerequisites
  2. The Hook: A Fingerprint Made of Isotopes
  3. Mass Spectrometry
  4. Electron Spectroscopy
  5. Microscopic Techniques
  6. Memory Tricks
  7. Don’t Confuse
  8. Common Mistakes
  9. Practice
  10. Quick Revision Table
  11. Key Takeaways
  12. What’s Next

Prerequisites

The Hook: A Fingerprint Made of Isotopes

Mass Spectrometry

A mass spectrometer forms gas-phase ions, separates them by mass-to-charge ratio (m/z) and counts them.

Ionisation methods

MethodHow ions formHard or softBest for
Electron ionisation (EI, usually 70 eV)electron beam knocks out an electron: M⁺•hard: extensive fragmentationvolatile, neutral, thermally stable compounds (metal carbonyls, metallocenes)
Chemical ionisation (CI)reagent-gas ions protonate or attachsofterM + H⁺ when EI shows no molecular ion
Fast atom bombardment (FAB) / LSIMSfast atoms or ions strike a liquid matrixsoftinvolatile salts, older method for complexes
Electrospray ionisation (ESI)charged droplets from a solution evaporatevery softionic and labile complexes, often seen as \( [\text{M} - \text{X}]^+ \), \( [\text{M} + \text{H}]^+ \), \( [\text{M} + \text{Na}]^+ \), multiply charged ions
MALDIlaser on the sample in a UV-absorbing matrixsoftclusters, polymers, large molecules
ICPargon plasma at several thousand kelvin atomises and ionisesdestroys the moleculeelemental and isotopic analysis at trace levels (ICP-MS)

Mass analysers

AnalyserPrincipleNotes
Magnetic sectorradius of path in a field depends on m/zdouble focusing gives high resolution
Quadrupolestable trajectories through oscillating fields for one m/z at a timecompact, unit resolution, common with GC and ICP
Time of flight (TOF)ions of equal kinetic energy fly a fixed distance; \( t \propto \sqrt{m/z} \)wide mass range; ideal with MALDI
Ion trap / Orbitrap / FT-ICRions oscillate at frequencies that depend on m/zvery high resolution and mass accuracy

Resolution \( R = m/\Delta m \), where Δm is the smallest separable mass difference at mass m. Nominal mass 28 covers CO (27.9949), N₂ (28.0061) and C₂H₄ (28.0313): separating CO from N₂ needs \( R \approx 28/0.0112 \approx 2500 \).

For TOF, all ions receive the same energy zeV, so

$$\frac{1}{2}mv^2 = zeV \quad\Rightarrow\quad t = L\sqrt{\frac{m}{2zeV}}$$

Doubling m/z multiplies the flight time by \( \sqrt 2 \); quadrupling it doubles the time.

Isotope patterns

Most inorganic elements have more than one isotope, so a molecular ion is a cluster whose shape identifies the elements present.

ElementIsotopes (approximate % abundance)Pattern for one atom
Cl³⁵Cl 75.8, ³⁷Cl 24.2M : M+2 ≈ 3 : 1
Br⁷⁹Br 50.7, ⁸¹Br 49.3M : M+2 ≈ 1 : 1
B¹⁰B 19.9, ¹¹B 80.1M−1 : M ≈ 1 : 4
Cu⁶³Cu 69.2, ⁶⁵Cu 30.8≈ 2.2 : 1
Ag¹⁰⁷Ag 51.8, ¹⁰⁹Ag 48.2≈ 1 : 1
Fe⁵⁶Fe 91.8, with ⁵⁴Fe 5.8, ⁵⁷Fe 2.1, ⁵⁸Fe 0.3dominated by 56
Sn, Mo, Ru, Hg, Ptmany isotopes (Sn has ten stable isotopes)broad multi-peak clusters
F, Na, Al, P, Mn, Co, As, Rh, I, Cs, Auone stable isotopesingle peak (monoisotopic)

For n atoms of an element with two isotopes in ratio a : b, the pattern is the expansion of \( (a + b)^n \):

Halogen contentM : M+2 : M+4 : M+6 (approx.)
Cl₂9 : 6 : 1
Br₂1 : 2 : 1
ClBr3 : 4 : 1
Br₃1 : 3 : 3 : 1
Cl₂Br9 : 15 : 7 : 1

Several elements: multiply (convolve) the separate patterns. For Cl₂Br, \( (9 : 6 : 1) \times (1 : 1) \) gives 9 : (9 + 6) : (6 + 1) : 1 = 9 : 15 : 7 : 1.

Charge state from isotope spacing

Isotopologues differ by about 1 u. In a peak cluster at charge z they appear 1/z apart on the m/z axis: spacing 1 → z = 1; spacing 0.5 → z = 2; spacing 0.33 → z = 3. Then the ion mass is (m/z) × z. ESI of multiply charged complexes and clusters relies on this.

Fragmentation of metal carbonyls (EI)

Successive loss of neutral CO (28 u) is the dominant pathway:

$$\text{Fe(CO)}_5^{+\bullet}\ (m/z\ 196) \to 168 \to 140 \to 112 \to 84 \to \text{Fe}^+\ (56)$$

Counting the 28-u steps from the molecular ion to the bare metal gives the number of carbonyls. In dinuclear carbonyls such as \( \text{Mn}_2(\text{CO})_{10} \) (nominal M = 390), both CO loss and metal–metal bond cleavage (giving \( \text{Mn(CO)}_5^+ \), m/z 195) appear. Ligand loss in general (phosphines, halides) follows weakest bonds first.

ICP-MS and isotope dilution

ICP-MS measures elements at very low concentrations (often ng L⁻¹ levels) and their isotope ratios. Isotope dilution adds a known amount of an enriched isotope to the sample; the measured change in isotope ratio gives the original amount without needing complete recovery.

Electron Spectroscopy

All electron spectroscopies measure the kinetic energy of electrons emitted from a sample. Because electrons travel only a few nanometres in a solid without losing energy, these methods are surface sensitive (top few nm) and need high vacuum.

X-ray photoelectron spectroscopy (XPS, ESCA)

Soft X-rays (Al Kα 1486.6 eV or Mg Kα 1253.6 eV) eject core electrons. Energy conservation:

$$\boxed{KE = h\nu - BE - \phi}$$

where BE is the binding energy (relative to the Fermi level) and φ the spectrometer work function.

What XPS gives:

  1. Elemental identity (core BEs are element-specific), all elements except H and He.
  2. Chemical (oxidation-state) shifts: a higher oxidation state or more electronegative neighbours raise the core BE (less screening of the core). Typical shifts are a few eV.
  3. Relative amounts: peak areas corrected by sensitivity factors.
  4. Spin–orbit doublets: p, d and f levels split into \( j = l \pm 1/2 \) with area ratios set by \( 2j + 1 \):
LevelComponentsArea ratio
p\( p_{1/2} \), \( p_{3/2} \)1 : 2
d\( d_{3/2} \), \( d_{5/2} \)2 : 3
f\( f_{5/2} \), \( f_{7/2} \)3 : 4

Classic chemical-shift examples:

CompoundObservationInterpretation
\( \text{Na}_2\text{S}_2\text{O}_3 \)two S 2p signals of equal area, several eV apartcentral S (high oxidation state, bonded to O) at higher BE; terminal S (sulfide-like) at lower BE
\( \text{NaN}_3 \)two N 1s signals, area 2 : 1two terminal N (formally negative) at lower BE; central N (formally positive) at higher BE

Shake-up satellites appear when the photoemission simultaneously excites a valence electron; the outgoing electron loses that energy and appears at apparently higher BE. Strong satellites in the Cu 2p spectrum are characteristic of Cu(II) (\( d^9 \)); Cu(I) and Cu(0) (\( d^{10} \)) lack them. This is a standard test of the copper oxidation state at surfaces.

Ultraviolet photoelectron spectroscopy (UPS)

He I (21.2 eV) or He II (40.8 eV) radiation ejects valence electrons from gaseous molecules or surfaces. By Koopmans’ theorem, each ionisation energy approximates the negative of an orbital energy, so a UPS spectrum is an experimental MO diagram.

Vibrational fine structure tells the bonding character of the orbital ionised:

Electron removed fromBond in the ionBand shape
strongly bonding MOweaker, longerlong vibrational progression; spacing smaller than in the neutral
non-bonding MOalmost unchangedsharp, short progression (mainly the 0–0 line)
antibonding MOstronger, shorterprogression with spacing larger than in the neutral

In N₂, the band from the \( 1\pi_u \) bonding orbital shows a long progression with reduced vibrational spacing, while the bands from the σ orbitals are much shorter, which is how the MO ordering of N₂ is checked experimentally.

Auger electron spectroscopy (AES)

A core hole (made by electrons or X-rays) is filled by an electron from a higher level; the released energy ejects a third electron, the Auger electron. Its kinetic energy depends only on the three levels involved (labelled, for example, KLL), not on the energy of the exciting beam. That is how Auger peaks are told apart from photoelectron peaks in an XPS spectrum: change the X-ray source and photoelectron KEs move while Auger KEs stay fixed.

  • Needs at least three electrons, so H and He are not detected.
  • Auger emission competes with X-ray fluorescence; Auger dominates for light elements, fluorescence for heavy ones.
  • With a focused electron beam, AES maps surface composition at high lateral resolution and, with ion sputtering, gives depth profiles.

X-ray emission in the electron microscope (EDX)

The same core holes, filled radiatively, emit characteristic X-rays whose frequencies follow Moseley’s law (\( \sqrt\nu \propto Z - \sigma \)). Energy-dispersive X-ray analysis (EDX/EDS) in an SEM or TEM gives the elemental composition of the imaged region.

Microscopic Techniques

Resolution of any microscope is limited by the wavelength of the probe. For light, the Abbe limit is about \( \lambda/(2\,\text{NA}) \), roughly 200 nm for visible light with the best objectives. Electrons accelerated through V volts have a de Broglie wavelength \( \lambda = h/\sqrt{2m_e eV} \) (relativistic correction needed at high voltage): about 3.7 pm at 100 kV and 2.5 pm at 200 kV. Practical resolution in TEM is limited by lens aberrations, not by λ, but still reaches the atomic scale.

TechniqueProbe and signalInformationSample needs
SEMfocused electron beam scanned over the surface; secondary electrons (SE), backscattered electrons (BSE), X-raysSE: surface topography; BSE: atomic-number contrast (heavier elements brighter); EDX: compositionconducting or coated with a thin conductive layer; vacuum
TEMelectrons transmitted through a thin specimenmorphology, particle size, lattice fringes (HRTEM), crystal structure by selected-area electron diffraction (SAED), EELSvery thin (tens of nm or less)
STEM-HAADFscanned focused beam; high-angle scattered electronsZ-contrast images: heavy atoms (Pt, Au) on light supports appear brightthin
STMsharp metal tip; quantum tunnelling current at a few ångströmsatomic-resolution topography and local density of electronic statesconducting surface
AFMsharp tip on a cantilever; deflection by tip–surface forcestopography, mechanical and frictional propertiesany surface: conductors, insulators, in air or liquid
graph TD
    A["What do you need?"] --> B["Formula, ligand count"]
    A --> C["Surface oxidation state"]
    A --> D["Image"]
    B --> B1["ESI / MALDI for complexes;
EI for volatile carbonyls;
ICP-MS for trace elements"] C --> C1["XPS (core BE shifts, satellites)"] C --> C2["AES (composition maps, depth profiles)"] D --> D1{"Conducting surface,
atomic resolution?"} D1 -->|"yes"| D2["STM"] D1 -->|"insulator or liquid"| D3["AFM"] D --> D4["Particle size, lattice: TEM/HRTEM;
morphology over µm: SEM"]

Memory Tricks

Don’t Confuse

ThisvsThat
EI: hard, fragments, volatile samplesESI/MALDI: soft, intact ions of salts and clusters
Nominal massexact (monoisotopic) mass, needs high R
XPS: core electrons, X-ray sourceUPS: valence electrons, He lamp
Photoelectron KE changes with hνAuger KE independent of hν
SEM: surface topography, thick samplesTEM: internal structure, thin samples
SE image: topographyBSE image: atomic-number contrast
STM: conductors, tunnelling currentAFM: any surface, interatomic forces

Common Mistakes

Practice

All questions below are original practice questions written for this page. They are not from any CSIR NET paper.

Level 1: Foundation

  1. What is the approximate M : M+2 : M+4 pattern of a molecule containing two Br atoms (no other polyisotopic element)?
  2. A photoelectron is ejected by Al Kα radiation (1486.6 eV) from a level of BE 285.0 eV; the spectrometer work function is 4.5 eV. What is its kinetic energy?
  3. Which microscope would you use for atomic-resolution images of an insulating mica surface?
Answers
  1. 1 : 2 : 1.
  2. \( KE = 1486.6 - 285.0 - 4.5 = 1197.1 \) eV.
  3. AFM (STM needs a conducting sample).

Level 2: Part B Style

Practice Q1. The most suitable method to record the intact molecular cation of an involatile salt \( [\text{Ru(bpy)}_3]\text{Cl}_2 \) is:

(a) EI at 70 eV (b) ESI (c) ICP-MS (d) GC-EI

Answer: (b) ESI

ESI transfers pre-formed ions from solution to the gas phase gently; it would show \( [\text{Ru(bpy)}_3]^{2+} \) (m/z = M/2) and possibly \( [\text{Ru(bpy)}_3\text{Cl}]^+ \). EI requires volatility; ICP destroys the molecule.

Practice Q2. In the EI mass spectrum of a mononuclear metal carbonyl, peaks appear at m/z 220, 192, 164, 136, 108, 80 and 52. The compound is:

(a) Ni(CO)₄ (b) Fe(CO)₅ (c) Cr(CO)₆ (d) Mo(CO)₆

Answer: (c) Cr(CO)₆

Six losses of 28 u from 220 down to 52 (⁵²Cr): \( 52 + 6 \times 28 = 220 \).

Practice Q3. The XPS spectrum of sodium thiosulfate shows:

(a) one S 2p signal (b) two S 2p signals of equal area (c) two S 2p signals in 3 : 1 ratio (d) no S signal, because sulfur is too light

Answer: (b)

The two sulfur atoms are in different environments (central S bonded to three O, terminal S): two chemically shifted signals, one atom each. (Each signal is itself a \( 2p_{3/2}/2p_{1/2} \) doublet, 2 : 1, if resolved.)

Practice Q4. In an XPS spectrum, a peak is found to stay at the same kinetic energy when the source is changed from Mg Kα to Al Kα. The peak is:

(a) a core photoelectron peak (b) a valence photoelectron peak (c) an Auger peak (d) a shake-up satellite

Answer: (c)

Photoelectron (and their satellite) kinetic energies shift by the change in hν (233 eV); Auger kinetic energies depend only on the atomic levels involved.

Level 3: Part C Style

Practice Q5. A neutral compound of a light element E (monoisotopic) contains two Cl and one Br. Using Cl 3 : 1 and Br 1 : 1, which statements about its molecular-ion cluster are correct?

  1. Four peaks appear, at M, M+2, M+4 and M+6.
  2. The intensity ratio is approximately 9 : 15 : 7 : 1.
  3. The most intense peak is M+2.
  4. The M+6 peak contains only ³⁷Cl₂⁸¹Br.

(a) 1, 2, 3 and 4 (b) 1 and 2 only (c) 2 and 3 only (d) 1, 3 and 4 only

Answer: (a) all four

\( (9 : 6 : 1) \) for Cl₂ convolved with \( (1 : 1) \) for Br: M = 9; M+2 = 9 + 6 = 15; M+4 = 6 + 1 = 7; M+6 = 1. M+2 is largest. The heaviest isotopologue, M+6, must contain both ³⁷Cl and ⁸¹Br. (With exact abundances the ratio is about 10.1 : 16.3 : 7.3 : 1.)

Practice Q6. An ESI spectrum of a cluster shows a peak envelope centred at m/z 1203.5 in which neighbouring isotope peaks are 0.33 units apart. A MALDI-TOF spectrum of the same sample, with 20 kV acceleration and a 1.5 m flight tube, shows a singly charged ion. Which statements are correct?

  1. The ESI ion carries a charge of 3+.
  2. The mass of the ESI ion is about 3610 u.
  3. In the TOF, an ion of m/z 4000 takes about twice as long as one of m/z 1000.
  4. An ion of m/z 1000 needs about 24 µs to reach the detector.

(a) 1, 2, 3 and 4 (b) 1 and 2 only (c) 3 and 4 only (d) 1, 3 and 4 only

Answer: (a) all four
  1. Spacing 1/z = 0.33 → z = 3. Correct.
  2. \( 1203.5 \times 3 = 3610.5 \). Correct.
  3. \( t \propto \sqrt{m/z} \); \( \sqrt{4000/1000} = 2 \). Correct.
  4. \( v = \sqrt{2zeV/m} = \sqrt{2(1.602\times10^{-19})(2.0\times10^4)/(1000 \times 1.661\times10^{-27})} = 6.21\times10^4 \) m s⁻¹; \( t = 1.5/6.21\times10^4 = 24 \) µs. Correct.

Practice Q7. A copper catalyst is examined by XPS before and after use. Before use, the Cu 2p region shows the \( 2p_{3/2} \) and \( 2p_{1/2} \) peaks with strong satellites at higher binding energy; after use, the satellites have vanished and the \( 2p_{3/2} \) peak has moved to lower binding energy. Which conclusions are justified?

  1. The fresh catalyst surface contains Cu(II).
  2. After use, the surface copper has been reduced to Cu(I) and/or Cu(0).
  3. The area ratio \( 2p_{3/2} : 2p_{1/2} \) is about 2 : 1 in both spectra.
  4. The data prove that the bulk of the catalyst has been reduced.

(a) 1, 2 and 3 only (b) 1 and 4 only (c) 2, 3 and 4 only (d) 1, 2, 3 and 4

Answer: (a) 1, 2 and 3 only
  1. Strong shake-up satellites are characteristic of \( d^9 \) Cu(II). Correct.
  2. Loss of satellites and a lower BE point to \( d^{10} \) Cu(I)/Cu(0) (telling these two apart usually needs the Auger parameter). Correct.
  3. For p levels, \( (2j + 1) \) gives 4 : 2 = 2 : 1. Correct.
  4. Wrong. XPS probes only the top few nanometres.

Quick Revision Table

IdeaFact
Soft ionisationESI (ionic complexes, multiply charged), MALDI (clusters, polymers), FAB
Hard ionisationEI 70 eV: fragments; carbonyls lose 28 u steps
Resolution\( R = m/\Delta m \); CO vs N₂ needs ≈ 2500
TOF\( t = L\sqrt{m/2zeV} \)
PatternsCl 3:1; Br 1:1; Cl₂ 9:6:1; Br₂ 1:2:1; ClBr 3:4:1; Cl₂Br 9:15:7:1
Chargeisotope spacing = 1/z
XPS\( KE = h\nu - BE - \phi \); Al Kα 1486.6, Mg Kα 1253.6 eV; BE rises with oxidation state
Spin–orbit areasp 1:2, d 2:3, f 3:4
ExamplesNa₂S₂O₃ two S 2p 1:1; NaN₃ N 1s 2:1; Cu(II) shake-up satellites
UPSHe I 21.2, He II 40.8 eV; Koopmans; long progression = bonding MO
AESKE independent of source; not H, He; dominates for light elements
MicroscopySEM topography/BSE Z-contrast/EDX; TEM lattice, SAED; HAADF Z-contrast; STM conductors; AFM anything
Wavelengthselectrons ≈ 3.7 pm at 100 kV, 2.5 pm at 200 kV; light ≈ 200 nm limit

Key Takeaways

What’s Next

Advertisement
Advertisement