Mass Spectrometry, Electron Spectroscopy and Microscopy
CSIR NET chemistry: ionisation methods, isotope patterns and charge states in MS; XPS, UPS and Auger; SEM, TEM, STM and AFM for inorganic materials.
- 17 min
On this page · 12 sections
Prerequisites
- Ionisation energies and Koopmans-type reasoning: Ionisation Energy and Electron Affinity.
- MO diagrams of N₂, CO and O₂ (what a photoelectron band removes): Bonding in Homonuclear Molecules.
- Binomial expansions for isotope patterns: Counting, Probability and Numbers.
- Microscopy in the life-science context (light, fluorescence, EM): Immunotechniques, Histochemistry and Microscopy.
The Hook: A Fingerprint Made of Isotopes
Mass Spectrometry
A mass spectrometer forms gas-phase ions, separates them by mass-to-charge ratio (m/z) and counts them.
Ionisation methods
| Method | How ions form | Hard or soft | Best for |
|---|---|---|---|
| Electron ionisation (EI, usually 70 eV) | electron beam knocks out an electron: M⁺• | hard: extensive fragmentation | volatile, neutral, thermally stable compounds (metal carbonyls, metallocenes) |
| Chemical ionisation (CI) | reagent-gas ions protonate or attach | softer | M + H⁺ when EI shows no molecular ion |
| Fast atom bombardment (FAB) / LSIMS | fast atoms or ions strike a liquid matrix | soft | involatile salts, older method for complexes |
| Electrospray ionisation (ESI) | charged droplets from a solution evaporate | very soft | ionic and labile complexes, often seen as \( [\text{M} - \text{X}]^+ \), \( [\text{M} + \text{H}]^+ \), \( [\text{M} + \text{Na}]^+ \), multiply charged ions |
| MALDI | laser on the sample in a UV-absorbing matrix | soft | clusters, polymers, large molecules |
| ICP | argon plasma at several thousand kelvin atomises and ionises | destroys the molecule | elemental and isotopic analysis at trace levels (ICP-MS) |
Mass analysers
| Analyser | Principle | Notes |
|---|---|---|
| Magnetic sector | radius of path in a field depends on m/z | double focusing gives high resolution |
| Quadrupole | stable trajectories through oscillating fields for one m/z at a time | compact, unit resolution, common with GC and ICP |
| Time of flight (TOF) | ions of equal kinetic energy fly a fixed distance; \( t \propto \sqrt{m/z} \) | wide mass range; ideal with MALDI |
| Ion trap / Orbitrap / FT-ICR | ions oscillate at frequencies that depend on m/z | very high resolution and mass accuracy |
Resolution \( R = m/\Delta m \), where Δm is the smallest separable mass difference at mass m. Nominal mass 28 covers CO (27.9949), N₂ (28.0061) and C₂H₄ (28.0313): separating CO from N₂ needs \( R \approx 28/0.0112 \approx 2500 \).
For TOF, all ions receive the same energy zeV, so
$$\frac{1}{2}mv^2 = zeV \quad\Rightarrow\quad t = L\sqrt{\frac{m}{2zeV}}$$Doubling m/z multiplies the flight time by \( \sqrt 2 \); quadrupling it doubles the time.
Isotope patterns
Most inorganic elements have more than one isotope, so a molecular ion is a cluster whose shape identifies the elements present.
| Element | Isotopes (approximate % abundance) | Pattern for one atom |
|---|---|---|
| Cl | ³⁵Cl 75.8, ³⁷Cl 24.2 | M : M+2 ≈ 3 : 1 |
| Br | ⁷⁹Br 50.7, ⁸¹Br 49.3 | M : M+2 ≈ 1 : 1 |
| B | ¹⁰B 19.9, ¹¹B 80.1 | M−1 : M ≈ 1 : 4 |
| Cu | ⁶³Cu 69.2, ⁶⁵Cu 30.8 | ≈ 2.2 : 1 |
| Ag | ¹⁰⁷Ag 51.8, ¹⁰⁹Ag 48.2 | ≈ 1 : 1 |
| Fe | ⁵⁶Fe 91.8, with ⁵⁴Fe 5.8, ⁵⁷Fe 2.1, ⁵⁸Fe 0.3 | dominated by 56 |
| Sn, Mo, Ru, Hg, Pt | many isotopes (Sn has ten stable isotopes) | broad multi-peak clusters |
| F, Na, Al, P, Mn, Co, As, Rh, I, Cs, Au | one stable isotope | single peak (monoisotopic) |
For n atoms of an element with two isotopes in ratio a : b, the pattern is the expansion of \( (a + b)^n \):
| Halogen content | M : M+2 : M+4 : M+6 (approx.) |
|---|---|
| Cl₂ | 9 : 6 : 1 |
| Br₂ | 1 : 2 : 1 |
| ClBr | 3 : 4 : 1 |
| Br₃ | 1 : 3 : 3 : 1 |
| Cl₂Br | 9 : 15 : 7 : 1 |
Several elements: multiply (convolve) the separate patterns. For Cl₂Br, \( (9 : 6 : 1) \times (1 : 1) \) gives 9 : (9 + 6) : (6 + 1) : 1 = 9 : 15 : 7 : 1.
Charge state from isotope spacing
Isotopologues differ by about 1 u. In a peak cluster at charge z they appear 1/z apart on the m/z axis: spacing 1 → z = 1; spacing 0.5 → z = 2; spacing 0.33 → z = 3. Then the ion mass is (m/z) × z. ESI of multiply charged complexes and clusters relies on this.
Fragmentation of metal carbonyls (EI)
Successive loss of neutral CO (28 u) is the dominant pathway:
$$\text{Fe(CO)}_5^{+\bullet}\ (m/z\ 196) \to 168 \to 140 \to 112 \to 84 \to \text{Fe}^+\ (56)$$Counting the 28-u steps from the molecular ion to the bare metal gives the number of carbonyls. In dinuclear carbonyls such as \( \text{Mn}_2(\text{CO})_{10} \) (nominal M = 390), both CO loss and metal–metal bond cleavage (giving \( \text{Mn(CO)}_5^+ \), m/z 195) appear. Ligand loss in general (phosphines, halides) follows weakest bonds first.
ICP-MS and isotope dilution
ICP-MS measures elements at very low concentrations (often ng L⁻¹ levels) and their isotope ratios. Isotope dilution adds a known amount of an enriched isotope to the sample; the measured change in isotope ratio gives the original amount without needing complete recovery.
Electron Spectroscopy
All electron spectroscopies measure the kinetic energy of electrons emitted from a sample. Because electrons travel only a few nanometres in a solid without losing energy, these methods are surface sensitive (top few nm) and need high vacuum.
X-ray photoelectron spectroscopy (XPS, ESCA)
Soft X-rays (Al Kα 1486.6 eV or Mg Kα 1253.6 eV) eject core electrons. Energy conservation:
$$\boxed{KE = h\nu - BE - \phi}$$where BE is the binding energy (relative to the Fermi level) and φ the spectrometer work function.
What XPS gives:
- Elemental identity (core BEs are element-specific), all elements except H and He.
- Chemical (oxidation-state) shifts: a higher oxidation state or more electronegative neighbours raise the core BE (less screening of the core). Typical shifts are a few eV.
- Relative amounts: peak areas corrected by sensitivity factors.
- Spin–orbit doublets: p, d and f levels split into \( j = l \pm 1/2 \) with area ratios set by \( 2j + 1 \):
| Level | Components | Area ratio |
|---|---|---|
| p | \( p_{1/2} \), \( p_{3/2} \) | 1 : 2 |
| d | \( d_{3/2} \), \( d_{5/2} \) | 2 : 3 |
| f | \( f_{5/2} \), \( f_{7/2} \) | 3 : 4 |
Classic chemical-shift examples:
| Compound | Observation | Interpretation |
|---|---|---|
| \( \text{Na}_2\text{S}_2\text{O}_3 \) | two S 2p signals of equal area, several eV apart | central S (high oxidation state, bonded to O) at higher BE; terminal S (sulfide-like) at lower BE |
| \( \text{NaN}_3 \) | two N 1s signals, area 2 : 1 | two terminal N (formally negative) at lower BE; central N (formally positive) at higher BE |
Shake-up satellites appear when the photoemission simultaneously excites a valence electron; the outgoing electron loses that energy and appears at apparently higher BE. Strong satellites in the Cu 2p spectrum are characteristic of Cu(II) (\( d^9 \)); Cu(I) and Cu(0) (\( d^{10} \)) lack them. This is a standard test of the copper oxidation state at surfaces.
Ultraviolet photoelectron spectroscopy (UPS)
He I (21.2 eV) or He II (40.8 eV) radiation ejects valence electrons from gaseous molecules or surfaces. By Koopmans’ theorem, each ionisation energy approximates the negative of an orbital energy, so a UPS spectrum is an experimental MO diagram.
Vibrational fine structure tells the bonding character of the orbital ionised:
| Electron removed from | Bond in the ion | Band shape |
|---|---|---|
| strongly bonding MO | weaker, longer | long vibrational progression; spacing smaller than in the neutral |
| non-bonding MO | almost unchanged | sharp, short progression (mainly the 0–0 line) |
| antibonding MO | stronger, shorter | progression with spacing larger than in the neutral |
In N₂, the band from the \( 1\pi_u \) bonding orbital shows a long progression with reduced vibrational spacing, while the bands from the σ orbitals are much shorter, which is how the MO ordering of N₂ is checked experimentally.
Auger electron spectroscopy (AES)
A core hole (made by electrons or X-rays) is filled by an electron from a higher level; the released energy ejects a third electron, the Auger electron. Its kinetic energy depends only on the three levels involved (labelled, for example, KLL), not on the energy of the exciting beam. That is how Auger peaks are told apart from photoelectron peaks in an XPS spectrum: change the X-ray source and photoelectron KEs move while Auger KEs stay fixed.
- Needs at least three electrons, so H and He are not detected.
- Auger emission competes with X-ray fluorescence; Auger dominates for light elements, fluorescence for heavy ones.
- With a focused electron beam, AES maps surface composition at high lateral resolution and, with ion sputtering, gives depth profiles.
X-ray emission in the electron microscope (EDX)
The same core holes, filled radiatively, emit characteristic X-rays whose frequencies follow Moseley’s law (\( \sqrt\nu \propto Z - \sigma \)). Energy-dispersive X-ray analysis (EDX/EDS) in an SEM or TEM gives the elemental composition of the imaged region.
Microscopic Techniques
Resolution of any microscope is limited by the wavelength of the probe. For light, the Abbe limit is about \( \lambda/(2\,\text{NA}) \), roughly 200 nm for visible light with the best objectives. Electrons accelerated through V volts have a de Broglie wavelength \( \lambda = h/\sqrt{2m_e eV} \) (relativistic correction needed at high voltage): about 3.7 pm at 100 kV and 2.5 pm at 200 kV. Practical resolution in TEM is limited by lens aberrations, not by λ, but still reaches the atomic scale.
| Technique | Probe and signal | Information | Sample needs |
|---|---|---|---|
| SEM | focused electron beam scanned over the surface; secondary electrons (SE), backscattered electrons (BSE), X-rays | SE: surface topography; BSE: atomic-number contrast (heavier elements brighter); EDX: composition | conducting or coated with a thin conductive layer; vacuum |
| TEM | electrons transmitted through a thin specimen | morphology, particle size, lattice fringes (HRTEM), crystal structure by selected-area electron diffraction (SAED), EELS | very thin (tens of nm or less) |
| STEM-HAADF | scanned focused beam; high-angle scattered electrons | Z-contrast images: heavy atoms (Pt, Au) on light supports appear bright | thin |
| STM | sharp metal tip; quantum tunnelling current at a few ångströms | atomic-resolution topography and local density of electronic states | conducting surface |
| AFM | sharp tip on a cantilever; deflection by tip–surface forces | topography, mechanical and frictional properties | any surface: conductors, insulators, in air or liquid |
graph TD
A["What do you need?"] --> B["Formula, ligand count"]
A --> C["Surface oxidation state"]
A --> D["Image"]
B --> B1["ESI / MALDI for complexes;
EI for volatile carbonyls;
ICP-MS for trace elements"]
C --> C1["XPS (core BE shifts, satellites)"]
C --> C2["AES (composition maps, depth profiles)"]
D --> D1{"Conducting surface,
atomic resolution?"}
D1 -->|"yes"| D2["STM"]
D1 -->|"insulator or liquid"| D3["AFM"]
D --> D4["Particle size, lattice: TEM/HRTEM;
morphology over µm: SEM"]Memory Tricks
Don’t Confuse
| This | vs | That |
|---|---|---|
| EI: hard, fragments, volatile samples | ESI/MALDI: soft, intact ions of salts and clusters | |
| Nominal mass | exact (monoisotopic) mass, needs high R | |
| XPS: core electrons, X-ray source | UPS: valence electrons, He lamp | |
| Photoelectron KE changes with hν | Auger KE independent of hν | |
| SEM: surface topography, thick samples | TEM: internal structure, thin samples | |
| SE image: topography | BSE image: atomic-number contrast | |
| STM: conductors, tunnelling current | AFM: any surface, interatomic forces |
Common Mistakes
Practice
All questions below are original practice questions written for this page. They are not from any CSIR NET paper.
Level 1: Foundation
- What is the approximate M : M+2 : M+4 pattern of a molecule containing two Br atoms (no other polyisotopic element)?
- A photoelectron is ejected by Al Kα radiation (1486.6 eV) from a level of BE 285.0 eV; the spectrometer work function is 4.5 eV. What is its kinetic energy?
- Which microscope would you use for atomic-resolution images of an insulating mica surface?
Answers
- 1 : 2 : 1.
- \( KE = 1486.6 - 285.0 - 4.5 = 1197.1 \) eV.
- AFM (STM needs a conducting sample).
Level 2: Part B Style
Practice Q1. The most suitable method to record the intact molecular cation of an involatile salt \( [\text{Ru(bpy)}_3]\text{Cl}_2 \) is:
(a) EI at 70 eV (b) ESI (c) ICP-MS (d) GC-EI
Answer: (b) ESI
ESI transfers pre-formed ions from solution to the gas phase gently; it would show \( [\text{Ru(bpy)}_3]^{2+} \) (m/z = M/2) and possibly \( [\text{Ru(bpy)}_3\text{Cl}]^+ \). EI requires volatility; ICP destroys the molecule.
Practice Q2. In the EI mass spectrum of a mononuclear metal carbonyl, peaks appear at m/z 220, 192, 164, 136, 108, 80 and 52. The compound is:
(a) Ni(CO)₄ (b) Fe(CO)₅ (c) Cr(CO)₆ (d) Mo(CO)₆
Answer: (c) Cr(CO)₆
Six losses of 28 u from 220 down to 52 (⁵²Cr): \( 52 + 6 \times 28 = 220 \).
Practice Q3. The XPS spectrum of sodium thiosulfate shows:
(a) one S 2p signal (b) two S 2p signals of equal area (c) two S 2p signals in 3 : 1 ratio (d) no S signal, because sulfur is too light
Answer: (b)
The two sulfur atoms are in different environments (central S bonded to three O, terminal S): two chemically shifted signals, one atom each. (Each signal is itself a \( 2p_{3/2}/2p_{1/2} \) doublet, 2 : 1, if resolved.)
Practice Q4. In an XPS spectrum, a peak is found to stay at the same kinetic energy when the source is changed from Mg Kα to Al Kα. The peak is:
(a) a core photoelectron peak (b) a valence photoelectron peak (c) an Auger peak (d) a shake-up satellite
Answer: (c)
Photoelectron (and their satellite) kinetic energies shift by the change in hν (233 eV); Auger kinetic energies depend only on the atomic levels involved.
Level 3: Part C Style
Practice Q5. A neutral compound of a light element E (monoisotopic) contains two Cl and one Br. Using Cl 3 : 1 and Br 1 : 1, which statements about its molecular-ion cluster are correct?
- Four peaks appear, at M, M+2, M+4 and M+6.
- The intensity ratio is approximately 9 : 15 : 7 : 1.
- The most intense peak is M+2.
- The M+6 peak contains only ³⁷Cl₂⁸¹Br.
(a) 1, 2, 3 and 4 (b) 1 and 2 only (c) 2 and 3 only (d) 1, 3 and 4 only
Answer: (a) all four
\( (9 : 6 : 1) \) for Cl₂ convolved with \( (1 : 1) \) for Br: M = 9; M+2 = 9 + 6 = 15; M+4 = 6 + 1 = 7; M+6 = 1. M+2 is largest. The heaviest isotopologue, M+6, must contain both ³⁷Cl and ⁸¹Br. (With exact abundances the ratio is about 10.1 : 16.3 : 7.3 : 1.)
Practice Q6. An ESI spectrum of a cluster shows a peak envelope centred at m/z 1203.5 in which neighbouring isotope peaks are 0.33 units apart. A MALDI-TOF spectrum of the same sample, with 20 kV acceleration and a 1.5 m flight tube, shows a singly charged ion. Which statements are correct?
- The ESI ion carries a charge of 3+.
- The mass of the ESI ion is about 3610 u.
- In the TOF, an ion of m/z 4000 takes about twice as long as one of m/z 1000.
- An ion of m/z 1000 needs about 24 µs to reach the detector.
(a) 1, 2, 3 and 4 (b) 1 and 2 only (c) 3 and 4 only (d) 1, 3 and 4 only
Answer: (a) all four
- Spacing 1/z = 0.33 → z = 3. Correct.
- \( 1203.5 \times 3 = 3610.5 \). Correct.
- \( t \propto \sqrt{m/z} \); \( \sqrt{4000/1000} = 2 \). Correct.
- \( v = \sqrt{2zeV/m} = \sqrt{2(1.602\times10^{-19})(2.0\times10^4)/(1000 \times 1.661\times10^{-27})} = 6.21\times10^4 \) m s⁻¹; \( t = 1.5/6.21\times10^4 = 24 \) µs. Correct.
Practice Q7. A copper catalyst is examined by XPS before and after use. Before use, the Cu 2p region shows the \( 2p_{3/2} \) and \( 2p_{1/2} \) peaks with strong satellites at higher binding energy; after use, the satellites have vanished and the \( 2p_{3/2} \) peak has moved to lower binding energy. Which conclusions are justified?
- The fresh catalyst surface contains Cu(II).
- After use, the surface copper has been reduced to Cu(I) and/or Cu(0).
- The area ratio \( 2p_{3/2} : 2p_{1/2} \) is about 2 : 1 in both spectra.
- The data prove that the bulk of the catalyst has been reduced.
(a) 1, 2 and 3 only (b) 1 and 4 only (c) 2, 3 and 4 only (d) 1, 2, 3 and 4
Answer: (a) 1, 2 and 3 only
- Strong shake-up satellites are characteristic of \( d^9 \) Cu(II). Correct.
- Loss of satellites and a lower BE point to \( d^{10} \) Cu(I)/Cu(0) (telling these two apart usually needs the Auger parameter). Correct.
- For p levels, \( (2j + 1) \) gives 4 : 2 = 2 : 1. Correct.
- Wrong. XPS probes only the top few nanometres.
Quick Revision Table
| Idea | Fact |
|---|---|
| Soft ionisation | ESI (ionic complexes, multiply charged), MALDI (clusters, polymers), FAB |
| Hard ionisation | EI 70 eV: fragments; carbonyls lose 28 u steps |
| Resolution | \( R = m/\Delta m \); CO vs N₂ needs ≈ 2500 |
| TOF | \( t = L\sqrt{m/2zeV} \) |
| Patterns | Cl 3:1; Br 1:1; Cl₂ 9:6:1; Br₂ 1:2:1; ClBr 3:4:1; Cl₂Br 9:15:7:1 |
| Charge | isotope spacing = 1/z |
| XPS | \( KE = h\nu - BE - \phi \); Al Kα 1486.6, Mg Kα 1253.6 eV; BE rises with oxidation state |
| Spin–orbit areas | p 1:2, d 2:3, f 3:4 |
| Examples | Na₂S₂O₃ two S 2p 1:1; NaN₃ N 1s 2:1; Cu(II) shake-up satellites |
| UPS | He I 21.2, He II 40.8 eV; Koopmans; long progression = bonding MO |
| AES | KE independent of source; not H, He; dominates for light elements |
| Microscopy | SEM topography/BSE Z-contrast/EDX; TEM lattice, SAED; HAADF Z-contrast; STM conductors; AFM anything |
| Wavelengths | electrons ≈ 3.7 pm at 100 kV, 2.5 pm at 200 kV; light ≈ 200 nm limit |
Key Takeaways
What’s Next
- Chapter quick revision: every number and rule from the six topics.
- Previous topic: Mössbauer and NQR Spectroscopy.
- Start of the chapter: IR and Raman Spectroscopy.
- The analytical side of inorganic chemistry in the f block: Analytical Applications.