Skip to content

Electrophysiology, Medical Imaging and Field Biology Methods

Patch clamp, voltage clamp, ECG, CT, MRI, fMRI, PET, mark-recapture, quadrats, behaviour sampling and remote sensing (NDVI) for CSIR NET Life Sciences.

  • 19 min read
  • Updated
On this page · 12 sections
  1. Prerequisites
  2. The Hook: A Gigaohm Seal and a Satellite
  3. Electrophysiological Methods
  4. Imaging the Living Body: CT, MRI, fMRI, PET
  5. Field Biology Methods
  6. Memory Tricks
  7. Don’t Confuse
  8. Common Mistakes
  9. Practice
  10. Quick Revision Table
  11. Key Takeaways
  12. What’s Next

Prerequisites

The Hook: A Gigaohm Seal and a Satellite

How CSIR NET asks it. Part B: patch-clamp configurations, what each ECG wave represents, which imaging method uses ionising radiation, BOLD signal basis, positron annihilation, Lincoln–Petersen assumptions, focal vs scan sampling, NDVI. Part C: single-channel current and conductance, Nernst potentials, heart rate from ECG paper, population estimates with Chapman’s correction, removal sampling, variance-to-mean dispersion, choosing imaging or sampling methods for a design.


Electrophysiological Methods

The electrical basics

  • Nernst potential of an ion (equilibrium potential):
$$E_{ion} = \frac{RT}{zF}\ln\frac{[\text{ion}]_{out}}{[\text{ion}]_{in}} \approx \frac{61.5\ \text{mV}}{z}\log_{10}\frac{[\text{ion}]_{out}}{[\text{ion}]_{in}}\ \ (37\ ^\circ\mathrm{C})$$
  • The resting potential lies close to E_K because resting membranes are most permeable to K⁺ (Goldman–Hodgkin–Katz equation weights each ion by its permeability).
  • Ohm’s law for channels: a single open channel of conductance γ carries current \(i = \gamma\,(V_m - E_{rev})\). The macroscopic current from N channels with open probability P₀ is \(I = N\,P_0\,i\).
  • Units to keep straight: 1 pS × 1 mV = 10⁻¹⁵ A; so 20 pS × 60 mV = 1.2 pA.

Recording configurations

MethodWhat it measuresNotes
Extracellular recordingSpikes and field potentials outside cellsMulti-electrode arrays, in vivo single units, EEG (scalp)
Intracellular (sharp electrode)Membrane potential of one cellDamages small cells
Current clampMembrane voltage while injecting set currentAction potentials, synaptic potentials
Voltage clampCurrent needed to hold voltage constantHodgkin and Huxley’s squid-axon analysis of Na⁺ and K⁺ currents (two-electrode clamp)
Patch clampCurrents through a small patch or whole cell, with a single pipetteNeher and Sakmann; Nobel Prize 1991

Patch-clamp configurations

graph TD
    CA["Cell-attached
gigaseal on intact cell
single channels,
cytoplasm undisturbed"] -->|"suction ruptures patch"| WC["Whole-cell
pipette continuous with cytoplasm
currents from whole membrane;
pipette solution dialyses cell"] CA -->|"pull pipette away"| IO["Inside-out patch
cytoplasmic face to bath
change intracellular ligands
(Ca2+, cAMP, ATP)"] WC -->|"pull pipette away"| OO["Outside-out patch
extracellular face to bath
apply neurotransmitters, drugs"]
  • Gigaseal (above 1 GΩ) lowers noise so picoampere currents are resolved; channel openings appear as rectangular steps between closed and open levels.
  • Perforated patch: antibiotics (amphotericin, nystatin, gramicidin) make small pores in the patch, giving whole-cell access while preserving cytoplasmic signalling molecules that whole-cell dialysis would wash out.
  • Pharmacological dissection: tetrodotoxin (TTX) blocks voltage-gated Na⁺ channels; tetraethylammonium (TEA) blocks many K⁺ channels.
  • Modern additions: optogenetics (light-gated channelrhodopsin drives activity), genetically encoded calcium indicators (GCaMP) and voltage dyes for imaging activity in many cells at once.

ECG (electrocardiogram)

The ECG records, from the body surface, the summed electrical activity of the heart. Willem Einthoven received the 1924 Nobel Prize for it.

ComponentRepresents
P waveAtrial depolarisation
PR intervalAtrial depolarisation + AV-node delay (normally about 0.12–0.20 s)
QRS complexVentricular depolarisation (atrial repolarisation is hidden in it)
ST segmentVentricles fully depolarised (plateau); elevation or depression indicates ischaemia/injury
T waveVentricular repolarisation
QT intervalTotal ventricular depolarisation + repolarisation; shortens as heart rate rises
  • Leads: standard bipolar limb leads I (right arm − to left arm +), II (right arm − to left leg +), III (left arm − to left leg +) form Einthoven’s triangle, with lead II = lead I + lead III; plus augmented limb leads (aVR, aVL, aVF) and six chest leads (V1–V6): 12 leads in all.
  • Standard paper: 25 mm/s; a small square (1 mm) = 0.04 s, a large square (5 mm) = 0.20 s; 10 mm = 1 mV.
  • Heart rate = 60 / RR interval (s) = 1,500 / (small squares between R waves) = 300 / (large squares).
  • Clinical uses: arrhythmias (heart block lengthens PR or drops QRS), infarction (ST and Q-wave changes), electrolyte disturbances (hyperkalaemia gives tall peaked T waves). Cardiac physiology is in blood and cardiovascular system.

Imaging the Living Body: CT, MRI, fMRI, PET

MethodPhysical basisIonising?StrengthLimitation
CT / CAT (computed (axial) tomography)X-ray attenuation measured from many angles, reconstructed into cross-sectionsYesFast; bone, lung, haemorrhage, traumaRadiation dose; poor soft-tissue contrast without contrast agents
MRI¹H nuclear magnetic resonance of water and fat in a strong field; RF pulses; relaxation times T₁ and T₂NoSuperb soft-tissue contrast (brain, spinal cord, joints)Slow, expensive; ferromagnetic implants and some pacemakers are contraindicated
fMRIBOLD contrast: local changes in deoxyhaemoglobinNoMaps brain activity non-invasively, mm resolutionIndirect and slow (seconds); measures blood response, not neurons
PETPositron emitters → annihilation → two 511 keV γ photons in opposite directions → coincidence detectionYesFunctional/metabolic imaging (glucose use, receptors, tumours)Lower spatial resolution; needs cyclotron-made short-lived isotopes
SPECT (related)Single γ emitters (e.g. ⁹⁹ᵐTc)YesPerfusion, bone scansLower resolution than PET

CT

  • An X-ray tube and detectors rotate around the patient; attenuation along thousands of paths is converted by tomographic reconstruction into slices.
  • Hounsfield units (HU): water = 0, air = −1,000; fat is negative, soft tissue slightly positive, bone strongly positive.
  • Hounsfield and Cormack shared the 1979 Nobel Prize in Physiology or Medicine. Iodinated contrast outlines vessels; PET-CT combines anatomy with function.

MRI

  • Protons align in the magnetic field (clinical scanners commonly 1.5 or 3 T); an RF pulse tips them; as they relax they emit signal. Gradient fields encode position.
  • T₁ (spin–lattice, longitudinal) recovery and T₂ (spin–spin, transverse) decay differ between tissues:
    • T₁-weighted: fat bright, water/CSF dark: anatomy.
    • T₂-weighted: water/CSF bright: oedema, inflammation, many lesions.
  • Gadolinium contrast (paramagnetic) shortens T₁ and brightens tissues where the blood–brain barrier leaks.
  • Variants: diffusion-weighted imaging (stroke), diffusion tensor imaging (white-matter tracts), MR angiography, MR spectroscopy (metabolites). Lauterbur and Mansfield shared the 2003 Nobel Prize for MRI. The physics is the same NMR described under biophysical methods.

fMRI and the BOLD signal

  • Deoxyhaemoglobin is paramagnetic; oxyhaemoglobin is diamagnetic. Deoxyhaemoglobin distorts the local field and shortens T₂*, lowering signal.
  • When a brain region becomes active, blood flow rises more than oxygen consumption (neurovascular coupling), so the deoxyhaemoglobin fraction falls and the BOLD signal rises.
  • The haemodynamic response lags neural activity by a few seconds; spatial resolution is millimetres. EEG and MEG have millisecond temporal resolution but poor localisation; combining them with fMRI is common.
  • Experimental designs: block or event-related task vs baseline, statistical maps corrected for multiple comparisons (see statistics).

PET

  • A tracer labelled with a positron emitter is injected. The positron travels a short distance, meets an electron and annihilates, producing two 511 keV photons at about 180°. Detector rings register coincident pairs; the line between them localises the event.
  • Isotopes: ¹⁸F (half-life about 110 min), ¹¹C (about 20 min), ¹³N (about 10 min), ¹⁵O (about 2 min); short half-lives need an on-site or nearby cyclotron.
  • ¹⁸F-FDG (fluorodeoxyglucose): taken up by glucose transporters and phosphorylated by hexokinase to FDG-6-phosphate, which is not metabolised further and is trapped; high signal in brain, heart and most tumours (Warburg effect). Other tracers image dopamine receptors, amyloid plaques, perfusion (¹⁵O-water).

Field Biology Methods

Estimating population density

MethodHowSuited to
Total count / censusCount every individualLarge, conspicuous animals in small areas; colonial birds
QuadratsCount in random or systematic plots of known areaPlants, sessile or slow animals
TransectsLine-intercept or belt transects along a gradientVegetation across ecotones; zonation
Plotless (point-centred quarter)Distance from random points to nearest individual in each quarter; density ≈ 1/(mean distance)²Trees, forest surveys
Distance samplingPerpendicular distances to animals seen from a line; fit a detection functionBirds, ungulates, primates
Mark–recaptureMark a sample, release, resampleMobile animals
Removal (depletion) samplingSuccessive catches without replacement declineFish (electrofishing), small mammals
Indirect indicesPellets, scats, nests, pugmarks, calls, catch per unit effortRelative abundance, elusive species
Camera trapsIndividuals identified from natural marks (e.g. stripe or spot patterns) feed capture–recapture modelsBig cats and other cryptic mammals
eDNASpecies DNA from water or soil (barcoding)Presence/absence of rare species

Quadrat measures (for a species over n quadrats):

  • Density = total individuals / total area sampled.
  • Frequency (%) = (quadrats in which the species occurs / total quadrats) × 100.
  • Abundance = total individuals / quadrats in which it occurs.
  • Quadrat size is chosen from a species–area curve (where adding area adds few new species).

Dispersion (spatial pattern) from quadrat counts: the variance-to-mean ratio \(s^2/\bar{x}\):

  • ≈ 1: random (Poisson);
  • < 1: uniform/regular (territoriality, competition);
  • 1: clumped/aggregated (patchy resources, social groups) — the commonest pattern in nature.

Mark–recapture

Lincoln–Petersen estimator for a closed population: mark M animals; later catch C, of which R are marked. Assuming the marked fraction in the sample equals that in the population (R/C = M/N):

$$\hat{N} = \frac{M\,C}{R} \qquad \text{Chapman's less biased form: } \hat{N} = \frac{(M+1)(C+1)}{R+1} - 1$$

Assumptions: closed population (no births, deaths, immigration, emigration between samples); marks are not lost or overlooked; marking does not affect survival or behaviour; marked animals mix randomly; all animals are equally catchable.

  • Trap-happy animals (attracted back to bait) inflate R and underestimate N; trap-shy animals lower R and overestimate N.
  • Multiple sessions: Schnabel method (closed population); Jolly–Seber models for open populations estimate survival and recruitment.

Removal sampling

If equal effort removes a constant fraction each time, two catches C₁ > C₂ give

$$\hat{N} = \frac{C_1^2}{C_1 - C_2}$$

With several passes, the Leslie method regresses catch per unit effort on cumulative catch; the x-intercept estimates N.

Tracking movement

Radio telemetry and GPS collars record locations; home range is estimated by the minimum convex polygon or kernel density methods; bio-loggers (accelerometers) record activity.

Behaviour sampling

Begin with an ethogram: a catalogue of defined behaviour patterns. Distinguish events (instantaneous: a call, a bite; measured as frequency) from states (durations: resting, foraging; measured as proportion of time). Classic framework from Altmann’s 1974 review, systematised in Martin and Bateson’s Measuring Behaviour.

Sampling rule (who to watch)What it isBest for
Ad libitumRecord whatever is visible and seems relevantPilot work; rare events; biased toward conspicuous acts
Focal (focal animal) samplingWatch one individual for a set period; record all its behaviourDetailed individual budgets, interactions
Scan samplingRapidly scan a group at set intervals and record each individual’s current behaviourGroup activity budgets (states)
Behaviour (all-occurrences) samplingWatch the whole group for one behaviour type and record every occurrenceRare, conspicuous events (fights, matings)
Recording rule (how to record)What it isGives
Continuous recordingEvery occurrence with start and stop timesTrue frequencies and durations
Instantaneous (point) samplingIs the behaviour occurring at the sample point?Good estimate of the proportion of time in a state when intervals are short
One–zero samplingDid it occur at any time during the interval?A score, not a true frequency or duration; tends to overestimate time spent

Reliability is checked by inter-observer agreement; observer effects (habituation of animals) and blind scoring reduce bias. Behavioural ecology theory is on the behavioural ecology page.

Remote sensing and GIS

  • Remote sensing: acquiring information about Earth’s surface without contact, from aircraft, drones or satellites, by measuring reflected or emitted electromagnetic radiation.
    • Passive sensors record reflected sunlight or emitted thermal radiation (multispectral and hyperspectral optical imagers).
    • Active sensors send their own signal: RADAR/SAR (works through cloud and at night), LiDAR (laser ranging: canopy height, forest structure).
  • Four resolutions: spatial (pixel size), spectral (number and width of bands), temporal (revisit time), radiometric (sensitivity, bit depth).
  • Spectral signature of vegetation: chlorophyll absorbs red (and blue); leaf internal structure reflects near-infrared (NIR) strongly. Hence
$$\mathrm{NDVI} = \frac{\mathrm{NIR} - \mathrm{Red}}{\mathrm{NIR} + \mathrm{Red}}, \qquad -1 \le \mathrm{NDVI} \le +1$$

Dense healthy vegetation gives high positive NDVI; sparse or stressed vegetation lower values; bare soil near zero; water typically negative.

  • GIS (geographic information system) overlays layers (land cover, elevation, roads, species records) for analysis; GPS gives ground positions; ground truthing validates classifications.
  • Uses: forest-cover and land-use change, habitat mapping and corridors, species distribution modelling, crop monitoring, fire and flood mapping, wetland and coral surveys.

Memory Tricks

  • Ionising imaging: CT and PET (and SPECT) use ionising radiation; MRI and fMRI do not.
  • Plants glow in NIR: healthy leaves absorb red and reflect near-infrared, so NDVI is high.

Don’t Confuse

ThisvsThat
Voltage clamp: hold V, measure IvsCurrent clamp: inject I, measure V
Inside-out: change cytoplasmic ligandsvsOutside-out: apply extracellular ligands
Whole-cell: dialyses cytoplasmvsPerforated patch: preserves cytoplasm
QRS: ventricular depolarisationvsT wave: ventricular repolarisation
CT: X-ray attenuation, ionisingvsMRI: proton relaxation, non-ionising
fMRI (BOLD): blood oxygenation, secondsvsEEG/MEG: electrical/magnetic, milliseconds
PET: positron → two 511 keV photonsvsSPECT: single γ photons
Lincoln–Petersen: closed population, one recapturevsJolly–Seber: open population, many occasions
Trap-happy: N underestimatedvsTrap-shy: N overestimated
Focal sampling: one animal, all behaviourvsScan sampling: all animals, snapshot
Instantaneous sampling: state at a pointvsOne–zero sampling: any occurrence in interval
Passive sensors: reflected/emitted radiationvsActive sensors: RADAR, LiDAR
Frequency (quadrats occupied)vsDensity (individuals per area) vs abundance (per occupied quadrat)

Common Mistakes


Practice

All questions below are original practice questions written in CSIR NET style. They are not previous-year questions.

Level 1: Foundation

  1. Which patch-clamp configuration lets you change the solution bathing the cytoplasmic face of a channel?
  2. Which ECG component represents ventricular depolarisation?
  3. In NDVI, which two spectral bands are used?
Answers
  1. Inside-out patch.
  2. The QRS complex.
  3. Near-infrared and red.

Level 2: Part B Style

Q1 (practice). In a pond, 60 newts are caught, marked and released. A week later 50 are caught, of which 12 are marked. The Lincoln–Petersen estimate and Chapman’s estimate of population size are, respectively:

  • (a) 250 and about 238
  • (b) 250 and about 262
  • (c) 10 and about 12
  • (d) 600 and about 250
Answer and explanation

(a). N = MC/R = 60 × 50 / 12 = 250. Chapman: (61 × 51)/13 − 1 = 3,111/13 − 1 = 239.3 − 1 ≈ 238.

Q2 (practice). On standard ECG paper (25 mm/s), consecutive R waves are 20 small squares apart. The heart rate is:

  • (a) 60 per min
  • (b) 75 per min
  • (c) 80 per min
  • (d) 120 per min
Answer and explanation

(b). RR = 20 × 0.04 s = 0.8 s; rate = 60/0.8 = 75 per min (equivalently 1,500/20).

Q3 (practice). At 37 °C, with [K⁺]out = 5 mM and [K⁺]in = 140 mM, the K⁺ equilibrium potential is closest to:

  • (a) +89 mV
  • (b) −61 mV
  • (c) −89 mV
  • (d) −140 mV
Answer and explanation

(c). E_K = 61.5 × log₁₀(5/140) = 61.5 × (−1.447) ≈ −89 mV.

Q4 (practice). Which imaging method relies on the paramagnetic property of deoxyhaemoglobin?

  • (a) PET with ¹⁸F-FDG
  • (b) CT
  • (c) BOLD fMRI
  • (d) SPECT
Answer and explanation

(c). BOLD contrast arises because deoxyhaemoglobin is paramagnetic and lowers the T₂*-weighted signal; activity-driven oversupply of oxygenated blood reduces it and raises the signal.

Level 3: Part C Style

Q1 (practice). An outside-out patch contains a ligand-gated channel. With agonist applied, rectangular current steps are recorded:

Holding potential (mV)Single-channel current (pA)
−80−2.4
−40−1.2
00
+40+1.2

(i) Calculate the single-channel conductance. (ii) What is the reversal potential, and what does it suggest about ion selectivity (assume physiological Na⁺ and K⁺ gradients)? (iii) If the patch contains 5 such channels each with open probability 0.2, what mean current is expected at −80 mV?

Answer and worked solution
  1. The i–V relation is linear through the origin: γ = Δi/ΔV = 2.4 pA / 80 mV = 30 pS (also 1.2 pA / 40 mV).
  2. E_rev = 0 mV. With E_Na near +60 mV and E_K near −90 mV, a reversal near 0 mV indicates a non-selective cation channel passing Na⁺ and K⁺ (as in the nicotinic acetylcholine receptor or glutamate AMPA receptors).
  3. I = N P₀ i = 5 × 0.2 × (−2.4 pA) = −2.4 pA on average.

Q2 (practice). A field team estimates a small-mammal population in a fenced 2-ha grassland.

  • Day 1: 80 voles captured, marked, released.
  • Day 4: 90 captured, 24 already marked.
  • A removal study in an adjacent fenced plot caught 100 voles on day 1 and 60 on day 2 (equal effort, none returned).

Which statements are correct?

(A) The Lincoln–Petersen estimate for the grassland is 300 voles, i.e. 150 per ha. (B) If marked voles learned to enter baited traps, the true population is probably larger than the estimate. (C) The removal estimate for the adjacent plot is 250 voles. (D) Lincoln–Petersen is suitable here only if births, deaths and movement between day 1 and day 4 are negligible.

  • (a) A, B, C and D
  • (b) A and C only
  • (c) B and D only
  • (d) A, C and D only
Answer and worked solution

(a) A, B, C and D.

  • (A) N = 80 × 90 / 24 = 300; 300/2 ha = 150 per ha. Correct.
  • (B) Trap-happy behaviour raises recaptures (R), so N̂ is an underestimate; the true population is likely larger. Correct.
  • (C) N = C₁²/(C₁ − C₂) = 100²/40 = 250. Correct.
  • (D) The closed-population assumption is essential. Correct (the fence helps with movement; the short interval limits births and deaths).

Q3 (practice). A conservation team compares two forest patches and two survey designs.

  • Satellite reflectance: patch P has NIR = 0.50, Red = 0.08; patch Q has NIR = 0.30, Red = 0.20.
  • Quadrat counts of a shrub in patch P (10 quadrats): 0, 2, 8, 0, 1, 9, 0, 0, 7, 3.

(i) Calculate NDVI for both patches and interpret. (ii) Calculate the variance-to-mean ratio of the shrub counts and state the dispersion pattern. (iii) To build an activity budget for a troop of 20 langurs in patch P, should the team use focal sampling with continuous recording or scan sampling with instantaneous recording? Justify briefly.

Answer and worked solution
  1. NDVI(P) = (0.50 − 0.08)/(0.50 + 0.08) = 0.42/0.58 ≈ 0.72; NDVI(Q) = (0.30 − 0.20)/0.50 = 0.20. P has dense, healthy green canopy; Q is sparse or degraded vegetation.
  2. Mean = 30/10 = 3.0; sample variance = 118/9 ≈ 13.1; ratio ≈ 4.4, well above 1: clumped distribution (patchy microhabitat or clonal growth).
  3. Scan sampling with instantaneous recording: it samples every visible individual at regular intervals and estimates the proportion of time the troop spends in each state (feeding, resting, moving), which is what an activity budget needs. Focal sampling with continuous recording gives richer data per individual but needs many hours per animal to cover 20 langurs; it is better for rare events or social interactions of particular individuals.

Quick Revision Table

ItemFact
NernstE = (61.5/z) log([out]/[in]) mV at 37 °C; E_K about −89 mV with 5/140 mM
Single channeli = γ(V − E_rev); I = N P₀ i
Patch configurationsCell-attached, whole-cell, inside-out (cytoplasmic face out), outside-out; gigaseal > 1 GΩ
Patch clampNeher and Sakmann, Nobel 1991; perforated patch preserves cytoplasm
BlockersTTX Na⁺ channels; TEA K⁺ channels
ECGP atrial depol; QRS ventricular depol; T ventricular repol; PR about 0.12–0.20 s
ECG leadsI, II, III (Einthoven’s triangle, II = I + III), aVR, aVL, aVF, V1–V6
Heart rate1,500 / small squares; 300 / large squares (25 mm/s)
CTX-ray attenuation; HU water 0, air −1,000; ionising
MRI¹H relaxation; T₁ fat bright; T₂ water bright; gadolinium; non-ionising
fMRIBOLD; deoxyHb paramagnetic; signal rises with activity; lag of seconds
PETPositron annihilation → two 511 keV photons at 180°; ¹⁸F-FDG trapped as FDG-6-P
QuadratDensity, frequency, abundance; species–area curve
Dispersions²/x̄: 1 random, < 1 uniform, > 1 clumped
Mark–recaptureN = MC/R; Chapman (M+1)(C+1)/(R+1) − 1; trap-happy underestimates
RemovalN = C₁²/(C₁ − C₂); Leslie regression
BehaviourAd libitum, focal, scan, all-occurrences; continuous, instantaneous, one–zero
Remote sensingPassive vs active (RADAR, LiDAR); spatial, spectral, temporal, radiometric resolution
NDVI(NIR − Red)/(NIR + Red); vegetation high, water negative